6. Remove thermopile from pilot bracket.
7. Reverse procedure to install.
PILOT ORIFICE
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS.
CHECK WITH SOAP AND WATER SOLUTION
(BUBBLES). DO NOT USE AN OPEN FLAME.
1. Remove pilot assembly from fryer as outlined
under thermopile.
2. Remove hex nut on the bottom of the pilot to
expose the orifice.
3. Replace orifice and reverse procedure to
assemble.
COMBINATION VALVE
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR LEAKS.
CHECK WITH SOAP AND WATER SOLUTION
(BUBBLES). DO NOT USE AN OPEN FLAME.
1. Disconnect fryer from main gas supply.
2. Remove heat shield as outlined under Covers
and Panels.
3. Remove right burner as outlined under
Burners.
4. Disconnect lead wires from combination valve
and mark for reconnecting.
5. Disconnect pilot tubing from combination
valve.