GPC SERIES GAS PASTA COOKERS
MODELS
GPC12
ML-126881
GPC12S
ML-126883
VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
F-31173 Rev. A (02-04)
INSTALLATION &
OPERATION MANUAL
For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanhart.com
P.O. BOX 696, LOUISVILLE, KY 40201-0696
TEL. (502) 778-2791
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - OPERATION MANUAL

GPC SERIES GAS PASTA COOKERSMODELSGPC12ML-126881GPC12SML-126883VULCAN-HARTDIVISION OF ITW FOOD EQUIPMENT GROUP, LLCF-31173 Rev. A (02-04)INSTALLATION

Page 2 - FOR YOUR SAFETY

– 10 –PL-41145WATER QUALITYThe water supply connected to this pasta cooker should contain no more than 2.0 grains of hardnessper gallon with pH from 6

Page 3 - TABLE OF CONTENTS

– 11 –OPERATIONWARNING: HOT WATER AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING,CLEANING AND SERVICING THE PASTA COOKER.WARNING: SPILLING HOT/

Page 4 - 2" (394 mm)

– 12 –THERMOSTAT —Controls temperature of water in tank. Temperature at "simmer"setting is approximately 190°F (88°C); burners will cycle o

Page 5 - INSTALLATION

– 13 –Fig. 10USING THE PASTA COOKERThe tank warranty may be voided by improper operation. Turn the power switch OFF when drainingor filling the pasta

Page 6

– 14 –2. Connect the power cord to an appropriate grounded receptacle.3. Turn the gas valve (located inside the cabinet door - see Fig. 9) to the ON p

Page 7 - PL-51493

– 15 –CookingDo not overfill basket.Recommended capacities are:Model Pounds of Spaghetti*GPC12 / GPC12S 7 (3 kg)*Amounts of different pasta, such as r

Page 8

– 16 –Fig. 12PL-41473-1SWIVEL HEAD FAUCETHOTCOLDCOOKERCOOKER CONTROLSCOOKER FILLVALVE (HOT)RINSE STATIONFILL VALVE(COLD)RINSESTATIONWithout Basketlift

Page 9

– 17 –HIGH LIMIT DEVICEIf the water level goes below the thermostat and high limit location (Fig. 13), the high limit will turn thepasta cooker off an

Page 10 - MODEL GPC12S

– 18 –Fig. 15The fill port spray nozzle allows the operator to see the tank filling with water. The fill port spray nozzlealso forces the foam and st

Page 11 - OPERATION

– 19 –3. Make sure drains (tank and overflow/skim) are unobstructed. Dried cooked pasta can clogdrains.4. Clean-out Brush• The clean-out brush is use

Page 12 - PL-53524

– 2 –IMPORTANT FOR YOUR SAFETYTHIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GASEQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD STAR

Page 13 - PL-51431

– 20 –F-31173 Rev. A (02-04) PRINTED IN U.S.A.MAINTENANCEWARNING: HOT WATER AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING,CLEANING AND SERVICIN

Page 14

– 3 –TABLE OF CONTENTSGENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 15

– 4 –Installation, Operation and Care ofMODEL GPC SERIES GAS PASTA COOKERKEEP THESE INSTRUCTIONS FOR FUTURE USEGENERALYour Vulcan Gas Pasta Cooker is

Page 16 - PL-41473-1

– 5 –Accessories Field InstallableCasters Round Angel Hair Pasta Baskets (set of 6)Bulk Single Cook Basket Bulk Single Angel Hair Pasta BasketRetherm

Page 17 - PL-40199-1

– 6 –INSTALLATION CODES AND STANDARDSYour Vulcan-Hart gas pasta cooker must be installed in accordance with:In the United States of America:1. State a

Page 18 - PL-41475-1

– 7 –Casters1. Position the pasta cooker in an open space near the final installation area.2. Tilt pasta cooker on its side. Be careful not to scratc

Page 19 - PL-41476

– 8 –GAS CONNECTIONSCAUTION: Gas supply connections and any pipe joint compound used must be resistant to theaction of propane gases.Codes require th

Page 20 - MAINTENANCE

– 9 –FLUE CONNECTIONSThe pasta cooker must be located under a hood which has an adequate connection to an exhaust duct.The hood must extend 6" (1