MGB-A OPERATING, INSTALLATION, SERVICE & PARTS
D. SERVICE
SERVICE TROUBLE SHOOTING GUIDE
PROBLEM POSSIBLE CAUSE
WHEN HEAT DOES NOT COME ON GAS VALVE BAD
WHEN CONTROL VALVE IS TURNED-ON PILOT BURNER NOT LIT
PILOT BURNER WILL NOT LIGHT MANUAL OR SAFETY SYSTEM GAS SYSTEM GAS
VALVE NOT TURNED ON
OBSTRUCTED PILOT ORIFICE
PILOT GAS TURNED OFF AT AUTOMATIC PILOT VALVE
AUTOMATIC VALVE BAD
PILOT BURNER WILL NOT STAY LIT THERMOCOUPLE BAD
THERMOCOUPLE NOT HOT ENOUGH
OBSTRUCTED OR WRONG SIZE PILOT ORIFICE
GAS SUPPLY NOT PURGED OF AIR
AIR BLOWING PILOT OUT
AUTOMATIC PILOT VALVE BAD
1. In order to remove burner for cleaning or replace-
ment:
(a) Remove the top grates
(b) Remove the radiants
(c) Remove the burners
(d) Reverse procedure for reassembly
2. To remove burner drawer:
(a) Turn off main shutoff valve
(b) Disconnect union
(c) Remove burner drawer screws, slide burner
drawer forward.