SERVICE MANUAL
GHF SERIES HEAVY DUTY
RANGE MATCHING GAS
FRYERS & FRYMATES
MODELS
GHF91G ML-135503
GHF90G ML-135504
- NOTICE -
This manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified. If you have attended a Vulcan Service School for this
product, you may be qualified to perform all the procedures
described in this manual.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you
should read, in it's entirety, the repair procedure you wish to
perform to determine if you have the necessary tools, instruments
and skills required to perform the procedure. Procedures for
which you do not have the necessary tools, instruments and
skills should be performed by a trained Vulcan Service
Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanhart.com
VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANHART.COM
P.O. BOX 696, LOUISVILLE, KY 40201-0696
TEL. (502) 778-2791
FORM 35618 (11-04)
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - SERVICE MANUAL

– 1 –SERVICE MANUALGHF SERIES HEAVY DUTYRANGE MATCHING GASFRYERS & FRYMATESMODELSGHF91G ML-135503GHF90G ML-135504- NOTICE -This manual is prepared

Page 2 - TABLE OF CONTENTS

– 10 –5. Allow temperature to stabilize at new settingand compare temperature tester to dial setting.Recalibrate if the temperature does not fallwithi

Page 3

– 11 –3. Turn on the gas and light the pilot as outlinedunder Lighting Pilot in General.4. Turn the combination valve to ON.5. Set the thermostat so t

Page 4 - COVERS AND PANELS

– 12 –3. Total Shutdown.A. When the high limit trips, 0.0 millivoltswill read across both coils of thecombination valve, causing both valvesto close.B

Page 5 - THERMOSTAT

– 13 –SCHEMATICCOMPONENT FUNCTIONThermostat - Millivolt type with capillary bulb, single-throw break on temperature rise. Temperature range of 200°Fto

Page 6 - HIGH LIMIT

– 14 –TROUBLESHOOTINGSYMPTOM1. The temperature of the shortening drops,or excessive recovery time is required.POSSIBLE CAUSEA. Insufficient gas supply

Page 7 - COMBINATION VALVE

– 15 –SYMPTOM4. Leaking tank.TROUBLESHOOTINGPOSSIBLE CAUSEA. Foam-over by depleted shortening permitsoil to drip from the tank surface, giving theappe

Page 8 - FRY TANK

– 16 –FORM 35618 (11-04) PRINTED IN U.S.A.NOTES

Page 9 - THERMOSTAT CALIBRATION

– 2 –© VULCAN-HART, 2004TABLE OF CONTENTSGENERAL ...

Page 10 - BURNERS, NOZZLES AND ORIFICES

– 3 –INTRODUCTIONModelsThis service manual was written for:GHF91G Gas Fryers and GHF90G Gas Frymates.INSTALLATIONGenerally, installations are made by

Page 11 - ADJUSTMENT

– 4 –COVERS AND PANELSWARNING: SHUT OFF THE GAS BEFORESERVICING.Door1. Open door and using a 5/16" wrench or ratchet,remove (2) screws securing

Page 12 - ELECTRICAL OPERATION

– 5 –THERMOSTATWARNING: SHUT OFF THE GAS BEFORESERVICING.1. Drain shortening from fry tank.2. Remove left burner as outlined under Burners.3. Remove

Page 13 - COMPONENT FUNCTION

– 6 –7. Pull the high limit bulb through the undersideof the fry tank and remove the high limitassembly.8. Reverse the procedure to install. Wheninsta

Page 14 - TROUBLESHOOTING

– 7 –6. Remove thermopile from pilot bracket.7. Reverse procedure to install.PILOT ORIFICEWARNING: SHUT OFF THE GAS BEFORESERVICING.WARNING: ALL GAS

Page 15

– 8 –FRY TANKWARNING: SHUT OFF THE GAS BEFORESERVICING.WARNING: ALL GAS JOINTS DISTURBED DURINGSERVICING MUST BE CHECKED FOR LEAKS.CHECK WITH SOAP A

Page 16

– 9 –SERVICE PROCEDURES AND ADJUSTMENTSMILLIVOLT CONTROLS TEST1. Verify proper gas (natural or propane) ispresent.2. Check for correct wiring and secu